MSYF-1 Block Limit Control System
描述
1. Introduction
MSYF-1(or MSFY-2) Block Limit Control System is a special electronic instrument to ensure the safe operation of workover rig. It is used to monitor the moving of traveling block within preset height and traveling speed range, prevent any overloading of hook, and record the ton kilometer value of wire line operation. Whatsapp +8615972752793 The system will warn the operator if ton kilometer value is over the preset maximum value, thus avoid any accident caused by the ageing wire line.
Advantages: Firm structure, simple installation, easy operation/setting, high reliability and user-friendly interfaces.
2. Major Technical Parameters
2.1 Height display range:-9.9m~+99.9m,Tolerance : ≤0.1 m.
2.2 Traveling speed display range: 0m/S~5m/S,error range : ≤0.1 m/S.
2.3 Hook load display range: 0kN~2000kN,Precision:≤1%F.S.
2.4 The ton kilometer value of traveling block: 0T. Km~9999.9T.Km,Tolerance: ≤0.1T.Km.
2.5 Braking response time: <0.1S. Whatsapp +8615972752793
2.6 Power supply: DC24v,≤50w.
2.7 Working temperature: -20℃~65℃.
2.8 The joint of encoder: Determined by the joint of the main drum
2.9 Language: Chinese or English.luben@youlongpetro.com
2.10 Ex-proof grade: ex-proof type dIIBT4 or intrinsic safety.
2.11 Protection grade: IP65.
3. Main Functions
3.1Display Function
3.1.1 Display current working state: Normal or Warning (Crown saver).
3.1.2 Digital display the height and traveling speed of traveling block, graphic display the height and direction of traveling block (Crown saver).
3.1.3 Digital display the hook load (ton kilometer display function). Whatsapp +8615972752793
3.1.4 Digital display the ton kilometer value of wire line operation (hook operational function).
3.1.5 Digital displays the total ton kilometer value of wire line operation (safety load function).
3.1.6 The working interface show as Picture 1 below:
(Picture 1)
Setting Function
3.2.1 Set the highest and lowest position of traveling block.
3.2.2 Set the maximum and minimum traveling speed range of traveling block.
3.2.3 Set the maximum loading value of the hook (Max ≤ 120 tons ).
3.2.4 Set the safety alarming ton kilometer value of wire line operation.
3.3 Protective Function luben@youlongpetro.com
3.3.1 Recognize the direction of the traveling block automatically.
3.3.2 Crown saver and floor saver.
3.3.3 When the traveling speed of traveling block over the preset value, the system will control the traveling of traveling block automatically and start brake function. luben@youlongpetro.com It is completed with audible and visual alarm so as to protect the traveling block operation safety.
3.3.4 When the hook load over preset value, the system will brake and stop operation automatically, disengage the main drum clutch so as to prevent the hook from overloading.
3.3.5 When the ton-kilometer value is over the preset safety value, it will start alarming system to protect the wire line operation safety.
4. Components list
| Number | Components | Component Model | Amount | Remarks |
| 1 | MSYF-1 (or MSYF-2)Unit | MSYF-1 | One set | |
| 2 | High-precision encoder | MSPF-1 | One set | |
| 3 | Installation joint | MD-SI-FYB-PJ-10 | One set | |
| 4 | Pressure transducer | MD-SJ-FYB-10 | One set | |
| 5 | Ex-proof wire box | MSYF-PJ-04 | One set | |
| 6 | Solenoid valve | MSYF-PJ-FESTO | One set | Optional |
| 7 | Shutter valve | MSYF-PJ-FESTO | One set | Optional |
| 8 | Power signal line | MSYF-PJ-3P | One piece | |
| 9 | Signal transmission line | MSYF-PJ-4P | One piece | |
| 10 | Signal transmission line | MSYF-PJ-5P | One piece | |
| 11 | The connection wire line of gas-act solenoid valve | MSYF-PJ-2P | One piece | Optional |
| 12 | Signal transmission line | MSYF-PJ-12P | One piece |